Kangaroo CK Spillway S.A.
Posted on Tuesday, August 28 th, 2018 by Duoguard no Comments.In 2017, TC Formwork approached Duoguard to look at using their Formtex PSA Formliner to assist in increasing the surface strength of the spillway and to reduce potential damage caused by cavitation. Formtex PSA has been an integral part of providing...
Continue -
Auckland Causeway
Posted on Monday, July 02 nd, 2018 by Duoguard no Comments.Auckland improves, widens and raises a 4.8km long section of motorway to provide additional capacity and to safeguard against coastal erosion and flooding. To help protect the newly improved causeway from corrosion a hybrid corrosion protection syst...
Continue -
Duoguard Distributing Formtex®
Posted on Thursday, August 11 th, 2016 by Duoguard no Comments.DuoGuard announces its “Durability in Design” program for Concrete Assets. DuoGuard Australia is now developing our ‘Durability in Design” range of products that will enhance new builds and remediate older structures to extend the life of cl...
Continue -
DuoGuard™ Hybrid Anode™ for Marine Structures
Posted on Friday, May 03 rd, 2013 by Duoguard no Comments.Dampier Salt Dolphins, Western Australia Applied treatment: DuoGuard™ Hybrid Anode™ Corrosion Control System Number of Anodes: 1700 (DuoGuard 500) Monitoring System: CPT Monitoring System (using MN15 Reference Electrodes) Project Length: July ...
Continue -
Rehabilitating an old concrete wharf incorporating DuoGuard™ Hybrid Anode™ corrosion control system
Posted on Tuesday, April 30 th, 2013 by Duoguard no Comments.The former Hmas Platypus submarine base precinct is to be rehabilitated and restored opening up a new public space for Sydney harbor and residents. The 216 m long steel reinforced concrete wharf structure is suffering from chloride attack and corrosi...
Continue -
DuoGuard™ Hybrid Anode™ Treatment for Northern Territory Lighthouse
Posted on Friday, April 12 th, 2013 by Duoguard no Comments.Cape Don Light House, Cobourg Peninsula, Northern Territory , AUSTRALIA Applied treatment: DuoGuard™ Hybrid Anode™ Corrosion Control System Number of Anodes: 4500 (DuoGuard D175,D500 and DuoGuard Plus Anodes ) Monitoring System: Remote Monitor...
Continue -
DuoGuard Plus™and DuoGuard Ultra™ Hybrid Anode™ System
Posted on Friday, April 12 th, 2013 by Duoguard no Comments.Product Update : New DuoGuard™ Hybrid Anode™ System DuoGuard Plus& Ultra are types of the DuoGuard Anode system designed to be used for application into the cover concrete in areas of high steel congestion wherer there is insufficient spac...
Continue -
PatchGuard Connect™Galvanic Anode System
Posted on Friday, April 12 th, 2013 by Duoguard no Comments.Product Update : New Galvanic Anode System PatchGuard Connect is a discrete sacrificial anode applied to reinforced concrete structures which are corroding as a result of chloride ingress or concrete carbonation.
Continue -
PatchGuard™ Galvanic Anode System
Posted on Tuesday, April 02 nd, 2013 by Duoguard no Comments.Berths B toF Appleton Dock Port of Melbourne Victoria Australia Applied treatment: PatchGuard TM Galvanic anode system Number of Anodes: 2500 PatchGuard TM Galvanic anodes Project Length: December 2012 – September 2013 Client : Port of M...
Continue -
DuoGuard™ Hybrid Anode™ for Industrial & Mining
Posted on Tuesday, April 03 rd, 2012 by Duoguard no Comments.Curragh Mine Thickener Tank, Australia Applied treatment: DuoGuard™ Hybrid Anode™ Corrosion Control System Number of Anodes: 12000 (DuoGuard 175&350) Monitoring System: CPT Monitoring System Project Length: January – April 2011 Client ...
Continue