Category : Projects
-
Kangaroo CK Spillway S.A.
Posted on Tuesday, August 28 th, 2018 by Duoguard no Comments.In 2017, TC Formwork approached Duoguard to look at using their Formtex PSA Formliner to assist in increasing the surface strength of the spillway and to reduce potential damage caused by cavitation. Formtex PSA has been an integral part of providing...
Continue -
595 Collins Street Melbourne
Posted on Wednesday, February 21 st, 2018 by development no Comments.PatchGuardPlus Connect™ Galvanic Anode™ for High Rise buildings Applied treatment: PatchGuardPlus Connect™ Corrosion Control System Number of Anodes: >5000 anodes Project Length: January – May2017 Client :Infracorr Consulting Contractors : Ve...
Continue -
Patterson Lakes
Posted on Thursday, February 15 th, 2018 by development no Comments.In 2017, the Duoguard hybrid anode system has been an instrumental part of repairs and corrosion protection undertaken by Melbourne Water on over 6 kilometres of steel reinforced concrete retaining wall at the Patterson Lakes tidal canals. This proje...
Continue -
DuoGuard™ Hybrid Anode™ for Marine Structures
Posted on Friday, May 03 rd, 2013 by Duoguard no Comments.Dampier Salt Dolphins, Western Australia Applied treatment: DuoGuard™ Hybrid Anode™ Corrosion Control System Number of Anodes: 1700 (DuoGuard 500) Monitoring System: CPT Monitoring System (using MN15 Reference Electrodes) Project Length: July ...
Continue -
Rehabilitating an old concrete wharf incorporating DuoGuard™ Hybrid Anode™ corrosion control system
Posted on Tuesday, April 30 th, 2013 by Duoguard no Comments.The former Hmas Platypus submarine base precinct is to be rehabilitated and restored opening up a new public space for Sydney harbor and residents. The 216 m long steel reinforced concrete wharf structure is suffering from chloride attack and corrosi...
Continue -
DuoGuard™ Hybrid Anode™ Treatment for Northern Territory Lighthouse
Posted on Friday, April 12 th, 2013 by Duoguard no Comments.Cape Don Light House, Cobourg Peninsula, Northern Territory , AUSTRALIA Applied treatment: DuoGuard™ Hybrid Anode™ Corrosion Control System Number of Anodes: 4500 (DuoGuard D175,D500 and DuoGuard Plus Anodes ) Monitoring System: Remote Monitor...
Continue -
PatchGuard™ Galvanic Anode System
Posted on Tuesday, April 02 nd, 2013 by Duoguard no Comments.Berths B toF Appleton Dock Port of Melbourne Victoria Australia Applied treatment: PatchGuard TM Galvanic anode system Number of Anodes: 2500 PatchGuard TM Galvanic anodes Project Length: December 2012 – September 2013 Client : Port of M...
Continue -
DuoGuard™ Hybrid Anode™ for Industrial & Mining
Posted on Tuesday, April 03 rd, 2012 by Duoguard no Comments.Curragh Mine Thickener Tank, Australia Applied treatment: DuoGuard™ Hybrid Anode™ Corrosion Control System Number of Anodes: 12000 (DuoGuard 175&350) Monitoring System: CPT Monitoring System Project Length: January – April 2011 Client ...
Continue